Understand how Linear Pluggable Optics (LPO) reduce 800G optical power and latency by removing the retiming DSP, and what that change means for host SerDes, signal integrity, interoperability, thermals and deployment.

800G optical links are becoming an increasingly important part of AI and high-performance computing networks, but increasing bandwidth also creates pressure on power, cooling and front-panel thermal density.

Traditional DSP-based optical transceivers perform significant signal conditioning and retiming inside the module. Linear Pluggable Optics (LPO) take a different approach. By removing the retiming DSP, LPO shifts more responsibility for signal integrity to the switch ASIC, host SerDes and equalization engines.

That architectural change can significantly reduce module power, heat and optical processing latency. The tradeoff is that electrical channel quality, host SerDes performance, firmware, FEC behavior and platform interoperability become more important to the performance of the complete link.

For an example of how Axiom implements LPO as an integrated 800G system, review the Axiom 800G Switch + LPO Solution .

Short Answer

What is Linear Pluggable Optics (LPO)?

Linear Pluggable Optics remove the retiming DSP found in conventional high-speed optical modules and rely more heavily on the switch and NIC SerDes to maintain signal integrity.

Removing that processing stage can lower module power, heat and optical processing latency. The tradeoff is greater dependence on the electrical channel, host SerDes, equalization, firmware, FEC and complete platform design.

What Changes When the Retiming DSP Is Removed?

The fundamental difference between LPO and traditional retimed optics is where signal conditioning occurs.

Optical Architecture
DSP-Based Optics vs. Linear Pluggable Optics
Traditional DSP-Based Optics
Switch ASIC
→
Host SerDes
→
Retiming DSP
→
Optical Engine

DSP-based modules perform digital equalization and signal conditioning inside the transceiver, helping compensate for channel loss, reflections, crosstalk, host impairments and PCB losses.

Linear Pluggable Optics (LPO)
Switch ASIC
→
Advanced SerDes
→
Linear Driver
→
Optical Engine

LPO removes the retiming DSP and shifts more signal-processing responsibility to the switch SerDes, NIC SerDes and ASIC equalization engines.

The Engineering Consequence

With LPO, the transceiver can no longer be evaluated as independently from the host platform as a DSP-retimed optic. Switch ASIC capability, SerDes performance, PCB channel quality, equalization, NIC behavior, FEC and firmware become more important parts of the link.

Why LPO Is Emerging With 800G AI Networks

AI infrastructure creates a strong use case for lower-power optical architectures because a large fabric can contain hundreds of switches and thousands of optical links.

Bandwidth
More GPU Traffic

Distributed AI training moves large amounts of east-west traffic between accelerator nodes and across the leaf-spine fabric.

Density
More Optical Links

Higher port counts increase the number of modules packed into the switch front panel, making per-module power increasingly important.

Thermals
More Heat to Remove

Optical-module power becomes heat at the front panel, where airflow and heat-sink space are constrained by high port density.

Latency
Repeated GPU Communication

Operations such as All Reduce, All Gather, Broadcast and Reduce Scatter repeatedly move data across the network during distributed training.

Where the LPO Power Savings Come From

Removing the retiming DSP can substantially reduce the power consumed by each 800G optical module.

Axiom engineering modeled an 800G DSP optic at 18W and an Axiom 800G LPO at 9W. That represents a 9W reduction per module, or approximately 50 percent in the modeled comparison.

Axiom Engineering Power Model
Modeled 800G Optical Module Power
DSP-Based 800G Optic 18W
Axiom 800G LPO 9W
9W modeled reduction per optical module
576W modeled optics-only reduction across 64 populated 800G ports
36.9 kW modeled direct reduction across 4,096 optical modules

These figures are modeled examples based on an 18W DSP module and 9W Axiom LPO. Actual module power and savings depend on the specific optic, reach, host platform, operating conditions and deployment.

Why Scale Changes the Power Conversation

A few watts per module may appear small when evaluating a single transceiver. Across thousands of continuously operating links, that difference can become tens of kilowatts of direct electrical load while also affecting cooling requirements and front-panel thermal density.

Review the complete cluster-scale power and TCO model in the Axiom 800G Switch + LPO Solution .

LPO vs. DSP-Based 800G Optics

LPO is not simply a lower-power version of the same architecture. Removing the retiming DSP changes where equalization happens and shifts more responsibility to the complete system.

Factor Linear Pluggable Optics (LPO) DSP / Retimed Optics
Retiming DSP No Yes
Module Power Lower Higher
Optical Processing Latency Lower Higher due to DSP processing
Heat Dissipation Lower Higher
Host SerDes Dependence Higher Lower
Electrical Channel Sensitivity Higher Lower
Channel Margin Tighter Greater
Interoperability Requirements More platform-dependent More mature across varied hosts
Tolerance to Poor Channel Quality Lower Higher
Supply Dependency No retiming DSP dependency Requires retiming DSP
Best Fit Controlled, high-density AI and HPC environments Broad or heterogeneous deployments
The Tradeoff

LPO trades some of the channel tolerance and host independence of DSP-retimed optics for lower power, reduced heat and lower optical processing latency. That makes system design and validation more important, not less.

LPO Changes the System Boundary

With a DSP-retimed module, the transceiver performs a significant amount of signal conditioning internally. With LPO, link performance depends more heavily on the complete electrical and optical path.

System-Level Link
The LPO Failure Domain Extends Beyond the Optical Module
Switch ASIC
→
SerDes / Equalization
→
PCB / Electrical Channel
→
LPO
→
Fiber
→
NIC / Host SerDes

If an LPO link becomes marginal or unstable, engineers may need to investigate more than the optical module itself. Potential contributors include:

  • Switch SerDes behavior
  • TX and RX equalization
  • Lane margin
  • PCB and connector channel loss
  • Host firmware
  • FEC configuration and behavior
  • NIC SerDes performance
  • Optical power
  • Module thermals
  • Fiber-path conditions

Where LPO Makes the Most Sense

LPO is strongest when the host platform, optics, electrical path and validation process can be engineered together.

Strong Candidate
AI Training Fabrics

High-density GPU clusters with sustained east-west traffic where optical power, latency and rack density are major design considerations.

Strong Candidate
HPC Networks

Scientific computing and message-passing environments where low communication latency and power-efficient high-speed links are important.

Strong Candidate
Dense RoCEv2 Fabrics

Controlled leaf-spine environments with high port counts, modern SerDes, predictable topology and strong telemetry.

Where DSP-Based Optics May Still Be the Better Fit
  • Heterogeneous brownfield environments
  • Platforms with uncertain SerDes capability
  • Electrical channels with limited margin
  • Deployments requiring broad third-party interoperability
  • Applications where maximum reach flexibility is more important than power
  • Environments without system-level qualification capability

What Engineers Must Validate Before Deploying LPO

Link-up is only the beginning. LPO qualification should prove the complete host-to-optic path.
LPO Qualification
A System-Level Validation Process
01 Optical TX/RX power
OMA
TDECQ
02 Signal Integrity PAM4
Equalization
Lane margin
03 BER + FEC Pre-FEC
Post-FEC
Error trends
04 Ethernet Throughput
Traffic stability
Latency
05 RoCEv2 PFC
ECN
RDMA
06 AI Workloads NCCL
GPU traffic
Stability
Physical Layer
Optical & Electrical Performance

Evaluate TX and RX optical power, OMA, TDECQ, receiver sensitivity, jitter, PAM4 behavior, equalization and electrical lane margin.

BER + FEC
Error Performance

Axiom's qualification framework targets pre-FEC BER better than 1E-4, post-FEC BER better than 1E-12, and zero uncorrectable errors during long-duration testing.

Host Platform
SerDes & Firmware

Verify switch ASIC, NIC, firmware, equalization settings, FEC behavior, port configuration and electrical-channel compatibility.

Traffic
Real Network Load

Test IMIX, large-message traffic, storage traffic, sustained Ethernet load and representative AI traffic rather than relying on basic link-up.

RoCEv2
Congestion Behavior

Validate PFC, ECN, RDMA throughput, buffers, queue stability, retransmissions, congestion recovery and deadlock behavior.

AI Workloads
Collective Communications

Qualification should include representative collective operations such as All Reduce, All Gather, Broadcast and Reduce Scatter.

Long-Duration Testing Matters

Axiom's engineering framework includes BER and stability testing across 24-hour, 72-hour, 7-day and 30-day periods. Extended testing helps expose marginal electrical channels, thermal behavior and intermittent errors that may not appear during a short link-up test.

Telemetry Becomes More Important With LPO

Because LPO shifts more signal-integrity responsibility toward the host, operators need visibility beyond whether the interface is simply up or down.

Link Health
Physical-Layer Telemetry

BER, FEC behavior, optical power, temperature, lane margin, PAM4 performance and link stability help identify marginal conditions before a hard failure occurs.

Fabric Health
Congestion Telemetry

ECN marking rates, PFC pause statistics, buffer occupancy, port utilization and congestion hot spots show how the broader Ethernet fabric is behaving.

Workload Health
Application Behavior

RDMA throughput, GPU communication behavior, retransmissions and workload stability help connect network conditions to actual AI application performance.

Troubleshooting LPO Requires a System-Level Approach

With LPO, an unstable link does not automatically mean the optical module has failed. The root cause may sit elsewhere in the host-to-host path.

Engineers may need to isolate the switch SerDes, equalization settings, electrical channel, optics, fiber path, remote host, NIC, firmware and FEC behavior one variable at a time.

An LPO Link Has a Larger Failure Domain

The more signal-conditioning responsibility that moves out of the module, the more important it becomes to diagnose the complete system rather than immediately replacing the optic.

For a production troubleshooting workflow, review the Optical Transceiver Failure Analysis Guide .

How Axiom Approaches Linear Pluggable Optics

Axiom approaches LPO as a system architecture rather than a standalone optical-module replacement.

Axiom's 800G implementation pairs Axiom Linear Pluggable Optics with an Axiom Broadcom Tomahawk 6-based network switch. The Axiom LPO is equalized for the Axiom switch platform, allowing the host electrical path and optical module to be engineered together.

The switch platform provides 102.4 Tbps of switching capacity, 64 x 800G OSFP front-panel interfaces, RoCEv2 support, PFC, ECN, MMU optimization and network telemetry for high-density AI and HPC Ethernet fabrics.

Axiom 800G Solution

See How Axiom Combines the Switch and LPO as One 800G Architecture

Review the Axiom Broadcom Tomahawk 6-based switch, Axiom 800G LPO, modeled power savings, RoCEv2 capabilities and integrated AI networking architecture.

Related Technical Resources

Integrated Solution
Axiom 800G Switch + LPO

See how Axiom combines a TH6-based switch with 800G LPO equalized for the platform.

Explore the Solution →

800G Optics
800G Optics Guide

Review 800G form factors, optical architectures, use cases and deployment considerations.

Review the Guide →

Validation
800G Transceiver Validation Guide

Review FEC, optical power, thermals, traffic stability and production qualification.

Review Validation →

AI Infrastructure
AI Networking Infrastructure Guide

Plan AI networking across switching, optics, NICs, interconnects, power and migration requirements.

Explore AI Networking →

Linear Pluggable Optics FAQs

What are Linear Pluggable Optics?

Linear Pluggable Optics, or LPO, remove the retiming DSP found in conventional high-speed optical modules and rely more heavily on switch and NIC SerDes capabilities, host equalization and the overall electrical channel to maintain signal integrity.

How does LPO reduce power consumption?

A major source of LPO power reduction is the removal of the retiming DSP from the optical module. In Axiom's modeled comparison, an 18W DSP-based 800G optic is compared with a 9W Axiom 800G LPO, representing approximately 50 percent lower optical-module power in that scenario.

Why can LPO reduce latency?

LPO removes the retiming DSP processing stage from the optical module. This reduces optical signal-processing delay compared with architectures that perform digital retiming within the transceiver.

What is the main tradeoff of LPO?

LPO reduces power and processing latency but becomes more dependent on the host platform. Switch SerDes performance, electrical channel quality, equalization, NIC behavior, FEC, firmware and interoperability become more important to overall link performance.

Does LPO require a special switch?

LPO requires a host platform with sufficiently capable SerDes and equalization for the target electrical channel and optical module. The complete switch, optics, firmware and NIC path should be qualified together rather than assuming any 800G host will behave identically.

Where does LPO fit best?

LPO is well suited to controlled, high-density AI and HPC networks where low optical power, lower processing latency, strong host SerDes and system-level validation are priorities. It is particularly relevant to large 800G leaf-spine and RoCEv2 fabrics.

When might DSP-based optics be a better choice?

DSP-retimed optics may remain a better fit in heterogeneous environments, electrical channels with limited margin, deployments requiring broad host interoperability, or applications where maximum channel tolerance and reach flexibility are more important than module power.

What should engineers validate before deploying LPO?

Engineers should evaluate optical power, PAM4 signal integrity, host SerDes, equalization, lane margin, BER, FEC, firmware, Ethernet traffic, RoCEv2 behavior, PFC, ECN, thermals, interoperability, telemetry, AI workloads and long-duration stability.

How does Axiom implement 800G LPO?

Axiom pairs its 800G Linear Pluggable Optics with an Axiom Broadcom Tomahawk 6-based network switch. The Axiom LPO is equalized for the Axiom switch platform, allowing the host electrical path and optical module to be engineered as an integrated 800G solution.

Evaluating LPO for an 800G AI or HPC Network?

Talk with Axiom about Linear Pluggable Optics, host SerDes requirements, 800G switching, power modeling, RoCEv2, interoperability and system-level qualification for your target environment.

Get fast pricing for your exact configuration and requirements.

Request a Quote
Find a compatible part
Find a compatible cable

Use our cable finder to find the right fiber, copper, DAC or AOC cable.

Search by cable type